Construction of RopeQuantityConstruction of StrandQuantityMin.breaking force factorNominal length mass factorNominal metallic cross-sectional area factor
strand6Wires

15 to 26K1=0,330W1=0,359C1=0,384
outer strand6Outer Wires7 to 12K2=0,356W2=0,400C2=0,449
layers of strand1Layers of wires2 to3
Wire in rope (excluding metallic core)90 to 156
Nominal rope diameter mmApproximate nominal length mass
kg/100m
Approximate nominal length mass
kg/100m
Minimum breaking force kNMinimum breaking force kNMinimum breaking force kNMinimum breaking force kNMinimum breaking force kN
Fiber CoreSteel CoreFiber Core 1770Steel Core 1770Fiber Core 1960Steel Core 1960Steel Core 2160
12345678
612,914,421,022,723,325,127,7
717,619,628,630,931,734,237,7
823,025,637,440,341,444,749,2
929,132,447,351,052,456,562,3
1035,940,058,463,064,769,876,9
1143,348,470,776,278,384,493,0
1251,757,684,190,793,1100111
1360,767,698,7106109118130
1470,478,4114124127137151
1691,9102150161166179197
18116130189204210226249
20144160234255259279308
22174194283305313338372
24207230336363373402443
26243270395426437472520
28281314458494507547603
32368410598645662715787
36465518787817838904997
405746409351012104011201230
4469577411301220125013501490
4882792213501450149016101770
52971108015801700175018902080
561130125018301980203021902410
601290144021002270233025102770

Accessibility Toolbar