Construction of Rope | Quantity | Construction of Strand | Quantity | Min.breaking force factor | Nominal length mass factor | Nominal metallic cross-sectional area factor |
---|---|---|---|---|---|---|
strand | 8 | Wires | 15 to 26 | K1=0,293 | W1=0,340 | C1=0,349 |
outer strand | 8 | Outer Wires | 7 to 12 | K2=0,356 | W2=0,407 | C2=0,457 |
layers of strand | 1 | Layers of wires | 2 to3 | |||
Wire in rope (excluding metallic core) | 120 to 208 |
Nominal rope diameter mm | Approximate nominal length mass kg/100m | Approximate nominal length mass kg/100m | Minimum breaking force kN | Minimum breaking force kN | Minimum breaking force kN | Minimum breaking force kN | Minimum breaking force kN |
---|---|---|---|---|---|---|---|
Fiber Core | Steel Core | Fiber Core 1770 | Steel Core 1770 | Fiber Core 1960 | Steel Core 1960 | Steel Core 2160 | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
8 | 21,8 | 26,0 | 33,2 | 40,3 | 36,8 | 44,7 | 49,2 |
9 | 27,5 | 33,0 | 42,0 | 51,0 | 46,5 | 56,5 | 62,3 |
10 | 34,0 | 40,7 | 51,9 | 63,0 | 57,4 | 69,8 | 76,9 |
11 | 41,1 | 49,2 | 62,8 | 76,2 | 69,5 | 84,4 | 93,0 |
12 | 49,0 | 58,6 | 74,7 | 90,7 | 82,7 | 100 | 111 |
13 | 57,5 | 68,8 | A87,6 | 106 | 97,1 | 118 | 130 |
14 | 66,6 | 79,8 | 102 | 124 | 113 | 137 | 151 |
16 | 87,0 | 104 | 133 | 161 | 147 | 179 | 197 |
18 | 110 | 132 | 168 | 204 | 186 | 226 | 249 |
20 | 136 | 163 | 207 | 252 | 230 | 279 | 308 |
22 | 165 | 197 | 251 | 305 | 278 | 338 | 372 |
24 | 196 | 234 | 299 | 363 | 331 | 402 | 443 |
26 | 230 | 275 | 351 | 426 | 388 | 472 | 520 |
28 | 267 | 319 | 407 | 494 | 450 | 547 | 603 |
32 | 348 | 417 | 531 | 645 | 588 | 715 | 787 |
36 | 441 | 527 | 672 | 817 | 744 | 904 | 997 |
40 | 544 | 651 | 830 | 1 010 | 919 | 1120 | 1 230 |
44 | 658 | 788 | 1 000 | 1 220 | 1 110 | 1350 | 1 490 |
48 | 783 | 938 | 1 200 | 1 450 | 1 320 | 1610 | 1 770 |
52 | 919 | 1 100 | 1 400 | 1 700 | 1 550 | 1890 | 2 080 |
56 | 1 070 | 1 280 | 1 630 | 1 980 | 1 800 | 2190 | 2 410 |
60 | 1 220 | 1 470 | 1 870 | 2 270 | 2 070 | 2510 | 2 770 |